Isophote Frequently Asked Questions

1. What are the basic equations relating harmonic amplitudes to geometrical parameter updates?

The basic elliptical isophote fitting algorithm, as described in Jedrzejewski (1987; MNRAS 226, 747), computes corrections for the current ellipse’s geometrical parameters by essentially “projecting” the fitted harmonic amplitudes onto the image plane:

\[{\delta}_{X0} = \frac {-B_{1}} {I'}\]
\[{\delta}_{Y0} = \frac {-A_{1} (1 - {\epsilon})} {I'}\]
\[{\delta}_{\epsilon} = \frac {-2 B_{2} (1 - {\epsilon})} {I' a_0}\]
\[{\delta}_{\Theta} = \frac {2 A_{2} (1 - {\epsilon})} {I' a_0 [(1 - {\epsilon}) ^ 2 - 1]}\]

where \(\epsilon\) is the ellipticity, \(\Theta\) is the position angle, \(A_i\) and \(B_i\) are the harmonic coefficients, and \(I'\) is the derivative of the intensity along the major axis direction evaluated at a semimajor axis length of \(a_0\).

2. Why use “ellipticity” instead of the canonical ellipse eccentricity?

The main reason is that ellipticity, defined as

\[\epsilon = 1 - \frac{b}{a}\]

better relates with the visual “flattening” of an ellipse. By looking at a flattened circle it is easy to guess its ellipticity, as say 0.1. The same ellipse has an eccentricity of 0.44, which is not obvious from visual inspection. The quantities relate as

\[Ecc = \sqrt{1 - (1 - {\epsilon})^2}\]

3. How is the radial gradient estimated?

The radial intensity gradient is the most critical quantity computed by the fitting algorithm. As can be seen from the above formulae, small \(I'\) values lead to large values for the correction terms. Thus, \(I'\) errors may lead to large fluctuations in these terms, when \(I'\) itself is small. This usually happens at the fainter, outer regions of galaxy images. Busko (1996; ASPC 101, 139) found by numerical experiments that the precision to which a given ellipse can be fitted is related to the relative error in the local radial gradient.

Because of the gradient’s critical role, the algorithm has a number of features to allow its estimation even under difficult conditions. The default gradient computation, the one used by the algorithm when it first starts to fit a new isophote, is based on the extraction of two intensity samples: #1 at the current ellipse position, and #2 at a similar ellipse with a 10% larger semimajor axis.

If the gradient so estimated is not meaningful, the algorithm extracts another #2 sample, this time using a 20% larger radius. In this context, a meaningful gradient means “shallower”, but still close to within a factor 3 from the previous isophote’s gradient estimate.

If still no meaningful gradient can be measured, the algorithm uses the value measured at the last fitted isophote, but decreased (in absolute value) by a factor 0.8. This factor is roughly what is expected from semimajor-axis geometrical-sampling steps of 10 - 20% and a deVaucouleurs law or an exponential disk in its inner region (r <~ 5 req). When using the last isophote’s gradient as estimator for the current one, the current gradient error cannot be computed and is set to None.

As a last resort, if no previous gradient estimate is available, the algorithm just guesses the current value by setting it to be (minus) 10% of the mean intensity at sample #1. This case usually happens only at the first isophote fitted by the algorithm.

The use of approximate gradient estimators may seem in contradiction with the fact that isophote fitting errors depend on gradient error, as well as with the fact that the algorithm itself is so sensitive to the gradient value. The rationale behind the use of approximate estimators, however, is based on the fact that the gradient value is used only to compute increments, not the ellipse parameters themselves. Approximate estimators are useful along the first steps in the iteration sequence, in particular when local image contamination (stars, defects, etc.) might make it difficult to find the correct path towards the solution. However, if the gradient is still not well determined at convergence, the subsequent error computations, and the algorithm’s behavior from that point on, will take the fact into account properly. For instance, the 3rd and 4th harmonic amplitude errors depend on the gradient relative error, and if this is not computable at the current isophote, the algorithm uses a reasonable estimate (80% of the value at the last successful isophote) in order to generate sensible estimates for those harmonic errors.

4. How are the errors estimated?

Most parameters computed directly at each isophote have their errors computed by standard error propagation. Errors in the ellipse geometry parameters, on the other hand, cannot be estimated in the same way, since these parameters are not computed directly but result from a number of updates from a starting guess value. An error analysis based on numerical experiments (Busko 1996; ASPC 101, 139) showed that the best error estimators for these geometrical parameters can be found by simply “projecting” the harmonic amplitude errors that come from the least-squares covariance matrix by the same formulae in Question 1 above used to “project” the associated parameter updates. In other words, errors for the ellipse center, ellipticity, and position angle are computed by the same formulae as in Question 1, but replacing the least-squares amplitudes by their errors. This is empirical and difficult to justify in terms of any theoretical error analysis, but it produces sensible error estimators in practice.

5. How is the image sampled?

When sampling is done using elliptical sectors (mean or median modes), the algorithm described in Jedrzejewski (1987; MNRAS 226, 747) uses an elaborate, high-precision scheme to take into account partial pixels that lie along elliptical sector boundaries. In the current implementation of the Ellipse algorithm, this method was not implemented. Instead, pixels at sector boundaries are either fully included or discarded, depending on the precise position of their centers in relation to the elliptical geometric locus corresponding to the current ellipse. This design decision is based on two arguments: (i) it would be difficult to include partial pixels in median computation, and (ii) speed.

Even when the chosen integration mode is not bilinear, the sampling algorithm resorts to it in case the number of sampled pixels inside any given sector is less than 5. It was found that bilinear mode gives smoother samples in those cases.

Tests performed with artificial images showed that cosmic rays and defective pixels can be very effectively removed from the fit by a combination of median sampling and sigma clipping.

6. How reliable are the fluxes computed by the Ellipse algorithm?

The integrated fluxes and areas computed by Ellipse were checked against results produced by the IRAF noao.digiphot.apphot tasks phot and polyphot, using artificial images. Quantities computed by Ellipse match the reference ones within < 0.1% in all tested cases.

7. How does the object centerer work?

The EllipseGeometry class has a find_center() method that runs an “object locator” around the input object coordinates.

This routine performs a scan over a 10x10 pixel window centered on the input object coordinates. At each scan position, it extracts two concentric, roughly circular samples with radii 4 and 8 pixels. It then computes a signal-to-noise-like criterion using the intensity averages and standard deviations at each annulus:

\[c = \frac{f_{1} - f_{2}}{{\sqrt{\sigma_{1}^{2} + \sigma_{2}^{2}}}}\]

and locates the pixel inside the scanned window where this criterion is a maximum. If the criterion so computed exceeds a given threshold, it assumes that a suitable object was detected at that position.

The default threshold value is set to 0.1. This value and the annuli and window sizes currently used were found by trial and error using a number of both artificial and real galaxy images. It was found that very flattened galaxy images (ellipticity ~ 0.7) cannot be detected by such a simple algorithm. By increasing the threshold value the object locator becomes stricter, in the sense that it will not detect faint objects. To turn off the object locator, set the threshold to a value >> 1 in Ellipse. This will prevent it from modifying whatever values for the center coordinates were given to the Ellipse algorithm.